When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG95330 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 30 port outlets capable of running at higher voltages, powers up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG95330 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 70.65 kg (131.4 kw equivalent of power consumption) of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.

Hydraulic-Magnetic Circuit Breaker
With the built-in hydraulic-magnetic circuit breaker in place, electricity supply can be automatically switched off to protect connected devices from getting overloaded or damaged, while maintaining stable power distribution.

Secure Locking Enhancement
The outlets can be protected with a secure lock to prevent power cords from becoming unplugged due to vibration or human errors.

Real-time Alerts via LCD Display
The illuminated LCD display can display warnings to alert users of unusual power states.

Hot-Swappable Function
The LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.

Dual LAN Ports for Scalable Network Setup
The PG95330 is equipped with dual LAN ports (e.g. Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.

Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.

Flexible On-Site Network Operation
For quick operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands. In addition, the same port is also functional as a PON port, available for Ethernet connection to a KN series KVM over IP Switch to centralize power management of up to 16 daisy-chained PDUs.

Networkable via WiFi
The PG95330 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.

Adjustable Power Cord for Flexible In-Rack Installation
The PG95330 comes with an adjustable power cord built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization.

DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.

Colored Panel for Smarter Power Monitoring
The PG series PDUs feature a LCD console panel in default red and can be re-colored with options of yellow, purple, blue, and green through optional purchase of colored stickers. These color codes make it easier to differentiate between power feed settings and also speed up troubleshooting in case of unexpected failures.

Applications
The PG series 3-Phase PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in a server room or data center.




Reasons to buy


  • 1 Gbps and 100 Mbps Ethernet ports
  • Allows for connecting up to 64 PDU units with cascading
  • ARM Cortex-A8 processor for flexible control methods via LAN / COM / USB / environmental sensor ports and enhanced monitoring via LCD console
  • Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking

Specification


Technical Description: ATEN 32A 30-Outlet 3Phase Metered PDU + Free Eco PDU Manager Software

Certificates
Compliance certificates:
CE

Certification
Compliance certificates:
CE

Design
Display:The description of display that can includes display type, resolution, size etc.
LCD
Product colour:
Black
Rack capacity:The spase that device fill in rack.
0U
Type:Characteristics of the device.
Three-phase
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Features
Cable length:How long the cable is.
3 m
Daisy chain:
Yes
Reset button:
Yes

Logistics data
Master (outer) case volume:
79853.5074 cm³
Master (outer) case gross weight:
11.2 kg
Master (outer) case height:
179 mm
Master (outer) case length:
1945 mm
Master (outer) case width:
229 mm
Master (outer) case net weight:
8.57 kg

Management features
Management protocols:
TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus
Supported network protocols:Network protocols tested as compatible with this product e.g. FTP,HTML, POP.
IPv6, SMS
Monitoring:
Current, Humidity, Power, Temperature, Voltage

Operational conditions
Operating relative humidity (H-H):
0 - 80%
Storage relative humidity (H-H):
0 - 80%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-20 - 60 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 60 °C

Packaging content
Rack mount kit:
Yes
Manual:
Yes

Packaging data
Package volume:
79853.5074 cm³
Package height:The distance from the top to the bottom of the packaging.
179 mm
Package depth:The distance from the front to the back of the packaging.
1945 mm
Package width:The distance from one side of the packaging to the other.
229 mm
Package weight:Weight of the packaged product.
10.8 kg

Ports & interfaces
USB ports quantity:
1
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
4
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
30 AC outlet(s)

Power
Circuit breaker:
Yes
Number of phases:
3
Load capacity:
22170 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
230 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
32 A
AC input frequency:
50 - 60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
400 V

Sustainability
Sustainability compliance:
Yes

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
8.41 kg
Height:The measurement of the product from head to foot or from base to top.
68 mm
Depth:The distance from the front to the back of something.
1790 mm
Width:The measurement or extent of something from side to side.
56 mm


Product details


PG95330G ATEN 4710469342981

ATEN 32A 30-Outlet 3Phase Metered PDU + Free Eco PDU Manager Software

£1463.99 and In stock

SKUPG95330G

ATEN 32A 30-Outlet 3Phase Metered PDU + Free Eco PDU Manager Software

Quick Code: Q1402564 MPN: PG95330G
£1463.99

In Stock
delivery_truck_speedOrder Now, and get it tomorrow, Friday 31st July