APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord

Quick Code: Q404948 MPN: AP8886
£1856.99

In Stock

Overview



APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.




Specification


Technical Description: APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord

Certificates
Certification:
EN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Compliance certificates:
RoHS

Certification
Certification:
EN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Compliance certificates:
RoHS

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Features
Cable length:How long the cable is.
1.83 m
LED indicators:
Yes

General
Type:Characteristics of the device.
Power Distribution Units (PDUs)

Logistics data
Total carbon footprint (kg of CO2e):
57837.86

Management features
Monitoring:
Current, Power, Voltage

Operational conditions
Non-operating altitude:
0 - 15000 m
Operating altitude:
0 - 3000 m
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 55 °C

Packaging data
Package height:The distance from the top to the bottom of the packaging.
2050 mm
Package depth:The distance from the front to the back of the packaging.
112 mm
Package width:The distance from one side of the packaging to the other.
170 mm
Package weight:Weight of the packaged product.
11.6 kg

Ports & interfaces
Output connections:
30 x IEC 320 C13 12 x IEC 320 C19
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
22000 W
Power protection features:Features that protect the device against power problems e.g. overload.
Overload
Maximum input current per phase:
32 A
Load capacity:
22080 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
230 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
32 A
AC input frequency:
50 - 60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
400 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
8.72 kg
Height:The measurement of the product from head to foot or from base to top.
1829 mm
Depth:The distance from the front to the back of something.
51 mm
Width:The measurement or extent of something from side to side.
56 mm


Product details


AP8886 APC

APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord

£1856.99 and In stock

SKUAP8886