Overview



APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager




Specification


Technical Description: APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19

Certificates
Certification:
EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI Class A, VDE
Compliance certificates:
RoHS

Certification
Certification:
EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI Class A, VDE
Compliance certificates:
RoHS

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered, Metered-by-outlet, Switched

Features
Cable length:How long the cable is.
3 m

Logistics data
Total carbon footprint (kg of CO2e):
7441.92

Management features
Outlet control:
Lock-out, Recycle, Turn off, Turn on
Monitoring:
Current, Power, Voltage

Operational conditions
Non-operating altitude:
0 - 15000 m
Operating altitude:
0 - 3000 m
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
-5 - 45 °C

Packaging data
Package height:The distance from the top to the bottom of the packaging.
2038 mm
Package depth:The distance from the front to the back of the packaging.
117 mm
Package width:The distance from one side of the packaging to the other.
162 mm
Package weight:Weight of the packaged product.
9.05 kg

Ports & interfaces
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
24 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
3680 W
Maximum total current draw per phase:
16 A
Maximum input current per phase:
16 A
Load capacity:
3680 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
230 V
AC input frequency:
50 - 60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
200-230 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
6.77 kg
Height:The measurement of the product from head to foot or from base to top.
1829 mm
Depth:The distance from the front to the back of something.
51 mm
Width:The measurement or extent of something from side to side.
56 mm


Product details


AP8659EU3 APC 0731304299516

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19

£1576.00 and In stock

SKUAP8659EU3

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19

Quick Code: Q42224 MPN: AP8659EU3
£1576.00

Quantity:
In Stock