Overview



APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.




Specification


Technical Description: APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309

Certificates
Certification:
UL 62368-1 CSA C22.2 No 62368-1 FCC part 15 subpart B CE EN 62368-1

Certification
Certification:
UL 62368-1 CSA C22.2 No 62368-1 FCC part 15 subpart B CE EN 62368-1

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
Type:Characteristics of the device.
Three-phase
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Features
Cable length:How long the cable is.
1.8 m

Logistics data
Total carbon footprint (kg of CO2e):
24171.76

Operational conditions
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
23 - 140 °F
Non-operating altitude:
0 - 15240 m
Operating altitude:
0 - 3048 m
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
-5 - 60 °C

Packaging data
Package height:The distance from the top to the bottom of the packaging.
1980 mm
Package depth:The distance from the front to the back of the packaging.
262 mm
Package width:The distance from one side of the packaging to the other.
132 mm
Package weight:Weight of the packaged product.
15.7 kg

Ports & interfaces
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C15 coupler, C19 coupler, C21 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)

Power
Number of phases:
3
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
60 A
AC input frequency:
50 - 60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
200 - 240, 346 - 415 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
12.7 kg
Height:The measurement of the product from head to foot or from base to top.
182.6 mm
Depth:The distance from the front to the back of something.
7.5 mm
Width:The measurement or extent of something from side to side.
5.6 mm


Product details


731304439752-XEX APC 0731304439752

APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309

£4489.00 and In stock

SKU731304439752-XEX


Parent Product

APDU10450SM APC


MPN: APDU10450SM

APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309

Quick Code: Q2928512 MPN: 731304439752-XEX
£4489.00

Quantity:
In Stock
delivery_truck_speedExpected Delivery Tuesday 28th July