Overview



As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE6216 eco PDU is an intelligent PDU that contains 16 AC outlets and are available in various IEC or NEMA socket configurations.

It provides secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors*.
1x PE6216 eco PDU
1x LIN2-314K-P426 Power Cord
1x Rack Mount Kit
1x CD ROM (Manual, eco Sensors Software)
1x User Instructions




At-a-glance



  • 3 x 7-segment front panel LED shows Current / IP Address for PDU / Bank

  • Current and voltage threshold setting

  • Easy setup and operation via a browser-based user interface

  • eco PDU Power Management software – eco Sensors

  • Environment monitoring – supports external temperature / humidity / Differential Pressure sensors for rack environment monitoring

  • Event logging and syslog support

  • IEC or NEMA outlet models

  • LED indicators for current and IP address at the PDU device and/or Bank levels

  • Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets

  • Multibrowser support (IE, Mozilla, Firefox, Chrome, Safari, Opera, Netscape)

  • Multilanguage support: English, Traditional Chinese, Simplified Chinese, Japanese, German, Italian, Spanish, French, Russian

  • Naming support for outlets

  • Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping, Telnet

  • Power status measurement at the PDU/Bank level

  • Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order

  • Proactive Overload Protection (POP) – automatically powers off outlets when current overloads to protect operating devices

  • Real-time aggregate current, voltage, and power and power dissipation displayed in a browser-based UI for monitoring at the PDU level

  • Remote power control via TCP/IP and a built in 10/100 Ethernet port

  • Remote users can monitor PDU/Bank status via web pages on their browsers

  • RTC support to keep the timer running during times of no power

  • Safe shutdown support

  • Separate power for the unit´s own power and its power outlets – the user interface is still accessible even when an overload condition trips the devices´ circuit breaker

  • Space saving 0U rack mount design with rear mounting

  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power

  • Supports SNMP Manager V1, V2 & V3

  • Up to 8 user accounts and 1 administrator account

  • Upgradeable firmware

  • User outlet access assignment on an outlet-by-outlet basis




Reasons to buy


  • 3 x 7-segment front panel LED shows Current / IP Address for PDU / Bank
  • Current and voltage threshold setting
  • Easy setup and operation via a browser-based user interface
  • eco PDU Power Management software – eco Sensors
  • Environment monitoring – supports external temperature / humidity / Differential Pressure sensors for rack environment monitoring
  • Event logging and syslog support
  • IEC or NEMA outlet models
  • LED indicators for current and IP address at the PDU device and/or Bank levels
  • Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets
  • Multibrowser support (IE, Mozilla, Firefox, Chrome, Safari, Opera, Netscape)
  • Multilanguage support: English, Traditional Chinese, Simplified Chinese, Japanese, German, Italian, Spanish, French, Russian
  • Naming support for outlets
  • Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping, Telnet
  • Power status measurement at the PDU/Bank level
  • Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
  • Proactive Overload Protection (POP) – automatically powers off outlets when current overloads to protect operating devices
  • Real-time aggregate current, voltage, and power and power dissipation displayed in a browser-based UI for monitoring at the PDU level
  • Remote power control via TCP/IP and a built in 10/100 Ethernet port
  • Remote users can monitor PDU/Bank status via web pages on their browsers
  • RTC support to keep the timer running during times of no power
  • Safe shutdown support
  • Separate power for the unit´s own power and its power outlets – the user interface is still accessible even when an overload condition trips the devices´ circuit breaker
  • Space saving 0U rack mount design with rear mounting
  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
  • Supports SNMP Manager V1, V2 & V3
  • Up to 8 user accounts and 1 administrator account
  • Upgradeable firmware
  • User outlet access assignment on an outlet-by-outlet basis

Specification


Technical Description: ATEN 16-Port Intelligent 0U Power Distribution Unit (PDU), Metered by Bank (2) & Switched by Outlet (14 x C13 & 2 x C19) 16Amp

Certificates
Certification:
CE, C-Tick TUV-CB, GOST

Certification
Certification:
CE, C-Tick TUV-CB, GOST

Design
Product colour:
Black
Rack capacity:The spase that device fill in rack.
0U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered, Switched

Features
Security algorithms:Security algorithms are used to provide authentication, cipher key generation, integrity and radio link privacy to users on mobile networks. The security algorithms supported are the ones that can be used with this product.
SNMP, SNMPv2, SNMPv3
Cable length:How long the cable is.
3 m
LED indicators:
Yes

Logistics data
Products per master (outer) case:
1 pc(s)
Master (outer) case gross weight:
6.02 kg
Master (outer) case height:
179 mm
Master (outer) case length:
1415 mm
Master (outer) case width:
187 mm
Master (outer) case net weight:
4.27 kg

Management features
Supported network protocols:Network protocols tested as compatible with this product e.g. FTP,HTML, POP.
TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, Ping, Telnet
Monitoring:
Current, Voltage

Operational conditions
Operating relative humidity (H-H):
0 - 80%
Storage relative humidity (H-H):
0 - 80%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-20 - 60 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C

Packaging content
Rack mount kit:
Yes
Manual:
Yes
Cables included:
AC

Packaging data
Package height:The distance from the top to the bottom of the packaging.
179 mm
Package depth:The distance from the front to the back of the packaging.
1415 mm
Package width:The distance from one side of the packaging to the other.
187 mm
Package weight:Weight of the packaged product.
6 kg

Ports & interfaces
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
1
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C20 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
16 AC outlet(s)

Power
Power protection features:Features that protect the device against power problems e.g. overload.
Overload
Load capacity:
3680 VA
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
16 A
AC input frequency:
50-60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
100-240 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
4.27 kg
Height:The measurement of the product from head to foot or from base to top.
44 mm
Depth:The distance from the front to the back of something.
66 mm
Width:The measurement or extent of something from side to side.
1324.8 mm


Product details


672792401268-XEX ATEN 0672792401268

ATEN 16-Port Intelligent 0U Power Distribution Unit (PDU), Metered by Bank (2) & Switched by Outlet (14 x C13 & 2 x C19) 16Amp