APC EPDU1010B-SCH power distribution unit (PDU) 7 AC outlet(s) 1U Black

Quick Code: Q1851605 MPN: 731304424505-XEX
£65.99

In Stock

Overview



It’s an Easy rack PDU basic model to be placed horizontally (19” rack-mountable) with 230VAC as nominal voltage Its input circuit is 10A with one C13 and six SCHUKO output receptacles The input cord length is 2.5m The housing material is aluminum extrusion Its operating condition is from -5°C to +45 °C, 5-95% RH non-condensing You can use four M6x16mm screws and four M6 cage nut for the rack mounting brackets It has CE certification with one year warranty




Specification


Technical Description: APC EPDU1010B-SCH power distribution unit (PDU) 7 AC outlet(s) 1U Black

Design
On/off switch:The button which is pressed to switch the device on or off.
No
Product colour:
Black
Housing material:
Aluminium
Mounting:
Horizontal
Rack capacity:The spase that device fill in rack.
1U
Type:Characteristics of the device.
Single-phase
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Basic

Features
Cable length:How long the cable is.
2.5 m

General
Type:Characteristics of the device.
Power Distribution Units (PDUs)

Logistics data
Total carbon footprint (kg of CO2e):
16.29

Ports & interfaces
AC outlet types:The type of outlet for AC electricity.
C13 coupler, Type F
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
7 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
2300 W
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
10 A
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
230 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
600 g
Height:The measurement of the product from head to foot or from base to top.
44.4 mm
Depth:The distance from the front to the back of something.
44.4 mm
Width:The measurement or extent of something from side to side.
482 mm


Product details


731304424505-XEX APC

APC EPDU1010B-SCH power distribution unit (PDU) 7 AC outlet(s) 1U Black

£65.99 and In stock

SKU731304424505-XEX


Parent Product

EPDU1010B-SCH APC


MPN: EPDU1010B-SCH